Smokeeter Model FS

Download Literature    Owners Manual

Specifications:

Dimensions: 46-5/8" Long x 20-5/8" Wide x 14-1/4" High
Weight:  102 Ibs.
CFM:  440-900 CFM
Motor:  1/4 Horse Power
Amps:  6 amps
Mounting Method:  Concealed

FS Smokeeters

FS and LS smoke eaters offer the ultimate in discreet and effective air cleaning for businesses that prioritize both air quality and aesthetics.

Designed to be installed above the ceiling, these concealed smoke eaters offer a visually seamless solution, making them ideal for environments where a sophisticated ambiance is paramount, such as bars, restaurants, casinos, hospitals, offices, and schools.

Despite their quiet operation, FS commercial air cleaners deliver impressive airflow ranges from 440 to 900 CFM, effectively filtering and circulating clean air throughout multiple rooms.

One of the standout features of the FS series is its ability to be ducted to various areas, thanks to its concealed installation above the ceiling. This flexibility allows for customized air distribution patterns, ensuring that every corner of your space receives fresh, purified air.

To further enhance the aesthetic appeal, FS smoke eaters can be seamlessly integrated with supply grilles, return grills, and flexible ductwork, creating a cohesive and visually pleasing system. Additionally, a wall-mounted remote switch offers convenient control, allowing you to adjust the air cleaning settings with ease.

For environments where odor control is a priority, the FS series offers an innovative solution – carbon modules. These separate units are designed with the same configuration as the FS smoke eaters, ensuring optimal odor neutralization and air pattern control.

How Do Concealed Smoke Eaters Work?

***NOTE: No changes to this:

Contaminated air is drawn into FS Smokeeter systems through waffle-shaped inlet grills or Return Air Assemblies (located in two separate areas).

The air then flows through Aluminized Flexible Ductwork and is directed to the smoke eater through a Wye Connection.

Once inside the smoke eater, pollutants are removed from the air stream through an aluminum mesh filter which removes larger particles.

The cleaned air is sent through ductwork and another Wye Connection and is then discharged into different locations through louvered outlet grills, or Supply Air Assemblies.

An activated carbon after-filter aids in controlling odor.

Jump To Units | Jump To Filters | Jump To Parts
Units
SKU Description  
01-0909 Smokeeter Model FS (Non-Package Unit)
480-885 CFM
Call For Pricing
Filters
SKU Description  
33-0053 Carbon Filter 11-1/2" x 18-1/2" x 1/4" (also in 800/FS)
$20.62
Qty:
33-0054 Filter-Mesh 11-1/2" x 18-1/2" x 3/4" (also in 800/SE 40)
$39.80
Qty:
45-0007 Smokeeter Detergent
30lbs. Box (Makes 300 Gallons)
$119.70
Qty:
Replacement Parts
SKU Description  
02-2141 Blower & Motor Assy. 11 5v VrSP
Call For Pricing
32-0083 Blower-Direct Drive 9-4 (also in SE 40/MC)
Call For Pricing
20-0569 Capacitator-12.5 MFD @ 370v
Call For Pricing
01-1177 Carbon Plenum Box
Call For Pricing
03-0306 Contact Kit-Unicell HV (also in 800/FC 1000/SE 40)
Call For Pricing
35-0174 Contact-Unicell HV (also in 800/FC 1000/SE 40)
Call For Pricing
42-0058 Gasket-Blower Flange
Call For Pricing
42-0163 Gasket-Blower Strut
Call For Pricing
03-0516 HV Lead Assy.
Call For Pricing
02-1318 HV Wire-Unicell (Cell to Contact)
Call For Pricing
02-1319 HV Wire-Unicell (Ionizer to Contact, was 20-0936)
Call For Pricing
37-0008 Insulator-Cell, Disk
Call For Pricing
37-0013 Insulator-Ceramic (1-1/2" L x 5/8" dia.)
Call For Pricing
03-0559 Ionizer Wire Springs (Set of 20)
Call For Pricing
39-0120 Knob-Switch, Vari-Speed (Black & Silver)
Call For Pricing
02-6411 Light & Switch Assy.-Remote (On/Off)
Call For Pricing
20-0556 Light-Pilot, Red (Rectangular)
Call For Pricing
02-1327 Motor 115v/1/60 Single Speed (also in
800SE/SE 40/MC, was 22-0067)
Call For Pricing
41-1171 Nameplate-SMOKEETER (also in LS)
Call For Pricing
30-0163 Nut-Spec Thd, J-Type (use w/30-01 65)
Call For Pricing
10-0157 Plate-Cell Narrow (hot)
Call For Pricing
10-0158 Plate-Cell Wide (ground)
Call For Pricing
10-1376 Plate-Cell/Ionizer
Call For Pricing
10-1372 Plate-End, Unicell
Call For Pricing
10-2375 Plate-Mounting, Blower
Call For Pricing
21-1218 Power Pack 115v Comm'l (also in HVRS)
Call For Pricing
03-0849 Power Pack Conversion Kit (21-1218 for
21-0058 Power Pack)
Call For Pricing
10-1375 Rail-Ionizer, 5 Wire (also in 800/FC 1000/SE 40)
Call For Pricing
30-0505 Receptacle (also in LS)
Call For Pricing
30-0504 Retainer (also in LS)
Call For Pricing
30-0164 Retainer-Wing Head Screw (use w/30-0165)
Call For Pricing
35-0191 Rod-Actuator, Switch
Call For Pricing
35-0175 Rod-Cell, Positive
Call For Pricing
30-0165 Screw-Spec Thds, Wing Head
Call For Pricing
35-0067 Spacer-Cell
Call For Pricing
36-0014 Spring-Contact (Cab to Ionizer/Cab to Cell)
Call For Pricing
10-2374 Strut-Blower
Call For Pricing
03-0528-SP Switch & light Assy.-Remote (Variable Speed)
Call For Pricing
20-2865 Switch, toggle (Must be used w/03-1 464)
Call For Pricing
20-0570 Switch-control, Vari-Speed (also in SE 40, 50,
24/LS, Pre-1996)
Call For Pricing
20-0436 Switch-Interlock (Double Pole)
Call For Pricing
02-1321-S Unicell (also in 800/FC 1000)
Call For Pricing
03-0393 Wire-Ionizer w/eyelets (was 02-1320)
Call For Pricing
03-0527 Wiring Harness-Cabinet
Call For Pricing
30-0503 Wiring Screw (also in LS)
Call For Pricing

FS Smokeeter Systems feature an innovative concealed concept that allows them the flexibility needed to adapt to any environment or room configuration. The standard components that are included with FS are the smoke eater itself and a wall-mounted remote control switch. The wide variety of accessories makes these air cleaning custom tailored to meet the needs of any room configuration.

Concealed Smokeeter Accessories
Carbon Plenum - The carbon module, or plenum, holds carbon and is used to combat strong, pervasive odors.

  • Twenty-gauge steel cabinet
  • 4 trays and holds 12 lbs. of carbon
  • 10" inlet/outlet collars. This allows the Carbon Plenum to connect to flexible or hard duct.
  • Supply Air Assembly - The Supply Air Assembly, or outlet grill, recirculates clean air into the room. It features a white enamel finish to blend with the ceiling and adjustable louvers. Supply Air Assemblies are available in these sizes:
  • 24" x 24" T-bar (12" x 12" grill) with 8" elbow
  • 24" x 24" T-bar (12" x 12" grill) with 10" elbow
  • Aluminized Flexible Duct - The Aluminized Flexible Duct allows users to channel air up to 25'. It is made of UL-listed aluminum polyester laminate with encapsulated galvanized steel wire, and can be compressed into just 32". Aluminized Flexible Duct is available in the following sizes:
  • 8" x 25'
  • 10" x 25'
  • 16" x 25'
  • Wye Connection - The Wye Connection is a device used to direct air to more than one area of a room. This transition piece can accept sheet metal or flexible duct.
  • 16" inlet with two 10" wye connections
  • 16" inlet with two 8" wye connections
  • 10" inlet with two 8" wye connections
  • Return Air Assembly - Designed to draw air into a concealed Smokeeter, the Return Air Assembly, or inlet grill, is made up of molded fiberglass plenum with scrim reinforced foil back and square-to-round collars. The molded white polystyrene eggcrate is 24" x 24" T-bar drop-in with 1/2" x 1/2" grid spacing.
  • 24" x 24" T-bar (12" x 12" grill) with 8" elbow
  • 24" x 24" T-bar (12" x 12" grill) with 10" elbow
  • Remote Switch Assembly - A standard accessory with concealed Smokeeters, the Remote Switch Assembly features a wall-mounted remote control with on/off switch and indicator light. The switch can be changed to an optional multiple speed control, and the lamp notifies users when the unit needs to be serviced.

    Smokeeter® is a registered trademark of United Air Specialists

    ADA Site Compliance-Accessibility Policy
    Trust Bar